Bullet Security Logo

DSC Takeover Guide

Before starting, verify the board model in the cabinet - (ie 1500, 1555, PC1616, PC1832, PC1864 etc). Try to obtain the installer code. Defaults code for ADT : 6321, 5555, 5010.

Links to user manuals :
DSC Power832 (PC5010)
DSC 1555MX
DSC PC1616, PC1808, PC1832, PC1864



1. Factory Default Panel

1. Disconnect AC power and battery.
2. Install jumper to short between Zone 1 and PGM1.
3. Reconnect AC power and wait until keypad beeps several times.
4. Remove the jumper and reconnect battery.

Keypad should now show a trouble light. Press *2 to see trouble, should be trouble code "8" (clock).





2. Set Clock

Press *6 then master user code (default is 1234)

Press 1

Enter the time and date in the following format :
Hour (24 HR clock), Hour, Minute, Month, Day, Year
HH MM MM DD YY

Example : for 4:35 pm on Feb 20th 2015 enter 1635022015
Example : for 11:15am on August 1st 2016 enter 1115080116

Press # to exit programming


3. Enter all new programming

Enter programming with *8 then 4 digit installer code (default is 5555).

Example : *8, 5555

Then enter a section to program (ex : 001, 310, 301 etc) and the paramters. Press # to exit programming and start over.

Step 1: Enter Zone Definitions

001

Ex : 001, 01,03,03,00,00,00

(6 zones, Z1 = entry/exit, Z2 = perimeter, Z3 = perimeter, Z4 = unused, Z5 = unused, Z6 = unused)


Step 2: CS Primary and Backup Phone #s

301, 302

Ex : 301, 18558566284
Ex : 302, 16049096572


Step 3: Enter account number

310

Ex : 310, 6801*66

(entered in 6 digit format - 4 digits plus FF)

Step 4: Entry/Exit Delays

005

Ex : 005, 01, 030, 030, 045

(30 second entry delay, 30 second secondary entry delay, 45 second exit delay)

Step 5: Check Parameters

013

Ensure 1 is on (NC Loops). Press 1 to toggle on/off

015

Ensure 7 is on (TLM enabled). Press 7 to toggle on/off

320
(Alarm Reporting Codes)

11, 11, 11, 11.. etc - until triple beep

324
(Alarm Restoral Reporting Codes)

11, 11, 11, 11.. etc - until triple beep

328
(Misc Alarm Reporting Codes)

11, 11, 11, 11.. etc - until triple beep

329
(Priority Alarm and Restoral)

11, 11, 11, 11.. etc - until triple beep

345
(Maintenance Alarm Reporting Codes)

11, 11, 11, 11.. etc - until triple beep

346
(Maintenance Restoral Reporting Codes)

11, 11, 11, 11.. etc - until triple beep

Step 5: Set Communicator Format

350

Ex : 350, 03, 03

(Set 03 03 for CONTACT ID format if doing Fire Alarm or 04 04 for SIA if doing burg)



Step 6: Set Communication Variables

377, 378

Ex : 377, 003, 003, 003, 000, 045, 010, 001 #

(Set Swinger shutdown, Communication Delay = 0 seconds, Daily Test (001)

Ex : 378, 2000

(Perform communications test at 8pm)

Step 7: Set Installer Code and Master User Code

006, 007

Ex : 006, 4444

(Set installer code as 4444 instead of default 5555)

Ex : 007, 2222

(Set master code as 2222 instead of default 1234)



Step 8: Add User Codes

Need Master User Code (default is 1234)

Enter *5, (master code), (user slot), (code) then # to exit

Ex : *5, 1234, 01, 2000, #

Changing slot 40 changes the Master User Code

Ex : *5, 1234, 40, 2222 #

(Set installer code as 4444 instead of default 5555)

 


4. Test

1. Arm the system using any 4 digit user code or master user code. Open and close the entry door to simulate leaving the building.

2. Once armed, proceed to trip each zone one by one as the siren sounds.

3. Disarm alarm to silence the siren.

4. Contact monitoring station and verify that all alarms were received on all zones.

 


NOTES

How to configure a zone connected to a keypad :

1. Enter programming (press *8, then installer code)

2. Enrol keypad (press 000, then 0, 18)

3. Assign Keypad Zone (020, then 00, 00, 00, 00, 00, 00, 00, 04) - this would assign the keypad zone into Zone 04.

4. Module Supervision Reset (press 902) - wait 1 minute for it to scan

5. Module Supervision Field (press 903)


How to Set up 2nd Partition

1. Enter Section 201 and enable partition 2.
Press 1,2,3, etc to Toggle Partition 1,2,3 on/off

2. Enter Partition Zone Assignment and toggle the zones on or off for those partitions/

Sec. 202 is Partition 1 Zones 1-8
Sec 203 is Partition 1 Zones 9-16
Sec 204 is Partition 1 Zones 17-24

Sec 210 is Partition 2, Zones 1-8
Sec 211 is Partition 2, Zones 9-16
Sec 212 is Partition 2, Zones 17-24

Example : You want Zone 7,8 in Partition 2.
Enter Sec 202 ,toggle OFF 7 and 8
Enter Sec 210, toggle ON 7 and 8

3. To make Keypad 2 arm/diarm Partition 2 :

FROM KEYPAD 2 :
Enter Programming, *8, installer code
Sec. 000 (keypad enrollment)
0
22
#
#